114
Event ID
(hex digit)
Severity Description Log Alert Summary Deal Method Memo
0320
(C0000140)
Fatal [Address Type 2 ] Medium Error was detected
in Physical Device but could not correct. %1
RO MA Physical Device
Medium
Error(Uncorrectable)
Please replace the Physical Device if too many
errors are detected on a Physical Device.
%1 : Logical Block
Address
0321
(40000141)
Information
[Address Type 2 ] Rebuild was paused. R
0322
(40000142)
Information
[Address Type 2 ] Rebuild was resumed. R
0323
(40000143)
Information
[Address Type 2 ] Rebuild was queued. R
0324
(80000144)
Warning [Address Type 2 ] Medium Error was detected
in Physical Device. %1
RO MA Physical Device
Medium Error
Detected
Please replace the Physical Device if too many
errors are detected on a Physical Device.
%1 : Logical Block
Address
1)
Information0401
(4000019
[Address Type 3 ] Logical Drive is Online. RO (M) Logical Drive Online None
0402
(80000192)
Warning [Address Type 3 ] Logical Drive is Degraded. RO (MA) Logical Drive
Degraded
If there is Hot Spare, RAID System will rebuild
automatically. If there is not it, please replace
the Physical Device and rebuild it.
. ne replace the Physical Device and
recreate the Logical Drive. Next restore the
p data to the Logical Drive.
0403
(C0000193)
Fatal [Address Type 3 ] Logical Drive is Offline RO (MA) Logical Drive Offli Please
backu
0404
(4 4) 000019
Information
[Address Type 3 ] Initialization was started. R
(4 5)
Information0405
000019
[Address Type 3 ] Initialization completed. R
0406
(C 6) 000019
Fatal [Address Type 3 ] Initialization failed. RO MA Initialization Failed Please retry Initialization. If Initialization failed
repeatedly, the RAID System may have some
kind of problem. Please deal with the problem
of the RAID System.
0407
(400000197)
Information
[Address Type 3 ] Initialization was stopped. R
0409
(40000199)
Information
[Address Type 3 ] Consistency Check was
started.
R
0410
(4000019A)
Information
[Address Type 3 ] Consistency Check
completed.
R
0411
(C000019B)
Fatal [Address Type 3 ] Consistency Check failed. RO MA Consistency Check
Failed
Please retry Consistency Check. If Consistency
Check failed repeatedly, the RAID System may
have some kind of problem. Please deal with
the problem of the RAID System.
0412
(4000019C)
Information
[Address Type 3 ] Consistency Check was
stopped.
R