Removing and Replacing a CPU-I/O Enclosure Cover
CRU Replacement Procedures 5-15
2. In the left pane of the Intel(R) PROSet for Wired Connections dialog box,
right-click the appropriate team. In the menu that appears, click Change Team
Mode (see Figure 5-6). Click a mode different from the one with the check mark.
NOTE
Changing the team mode forces PROSet to update the
Ethernet address of the team.
Figure 5-6. Changing the Mode of an Ethernet Team
3. Again, right-click the team in the device tree in the left pane, and, on the menu that
appears, click Change Team Mode. Verify that the mode has been changed.
4. Click OK to allow PROSet to process the procedure and to close. Allow PROSet
time to process the update, approximately 30 seconds.
5. Restart PROSet and restore the team to its previous mode.
6. Click Apply to process and save the changes. Again, allow PROSet processing
time.
7. Reconnect the network cables to the embedded Ethernet PCI adapter ports and
verify network connectivity.
Removing and Replacing a CPU-I/O Enclosure Cover
Remove the cover of a CPU- I ⁄ O enclosure to access the CRUs located within it.
Estimated time: One minute.
Tools: ESD strap and #2 Phillips head screwdriver.