User's Guide Express5800 Series Ver.1.00© NEC Corporation 2014NEC ESMPRO Manager Ver.6 Command Line Interface Chapter1 About Command Lin

Página 2 - Contents

9 Chapter2 Command Summary 2.1 Group management Commands 2.1.1 getList Syntax: dscli getList GroupName [/g] [/x] Description: Displays the li

Página 3

10 Displays the list of groups and components. The following shows an example. >dscli getList root group1 <GROUP> group2 <GROUP&

Página 4

11 2.1.2 createGroup Syntax: dscli createGroup GroupName [ParentGroupName] Description: Creates a new component group. Options: GroupName Spe

Página 5

12 2.1.5 setGroupProperty Syntax: dscli setGroupProperty GroupName PropertyName Value Description: Sets the property of a group. Options: Group

Página 6 - About This Document

13 2.1.7 getGroupStatus Syntax: dscli getGroupStatus GroupName Description: Displays the status of a specified component group. Among all compone

Página 7 - 1.1 System Requirements

14 2.1.8 groupPowerOn Syntax: dscli groupPowerOn GroupName [/p] [/exs ComponentName1 ComponentName2 ... ComponentNameN] [/exg GroupName1 GroupName

Página 8 - 1.2 How to Execute Commands

15 2.1.9 groupPowerOff Syntax: dscli groupPowerOff GroupName [/exs ComponentName1 ComponentName2 ... ComponentNameN] [/exg GroupName1 GroupName2 .

Página 9 - Manager

16 2.1.10 groupReset Syntax: dscli groupReset GroupName [/p] [/exs ComponentName1 ComponentName2 ... ComponentNameN] [/exg GroupName1 GroupName2 ..

Página 10 - Chapter2 Command Summary

17 2.1.11 groupPowerCycle Syntax: dscli groupPowerCycle GroupName [/p] [/exs ComponentName1 ComponentName2 ... ComponentNameN] [/exg GroupName1 Gro

Página 11

18 2.1.12 groupShutdownOs Syntax: dscli groupShutdownOs GroupName [/force] [/exs ComponentName1 ComponentName2 ... ComponentNameN] [/exg GroupName1

Página 12 - 2.1.4 moveGroup

1 Contents Contents...

Página 13 - 2.1.6 getGroupProperty

19 2.1.13 groupSetPowerRestoreDelay Syntax: dscli groupSetPowerRestoreDelay GroupName DelayTime [/x Policy] [/exs ComponentName1 ComponentName2 ...

Página 14 - 2.1.7 getGroupStatus

20 Output: If error has occurred, the name and the error message about each error-occurred managed component is displayed. The following shows an ex

Página 15 - 2.1.8 groupPowerOn

21 2.2 Component Management Commands 2.2.1 getServerList Syntax: dscli getServerList [/d] Description: Displays the name list of all managed co

Página 16 - 2.1.9 groupPowerOff

22 2.2.2 getServerNameByMacAddr Syntax: dscli getServerNameByMacAddr MacAddress Description: Displays the name of the managed component that has

Página 17 - 2.1.10 groupReset

23 2.2.4 findNewServer Syntax: dscli findNewServer StartIpAddr EndIpAddr Description: Finds BMC on managed components that are not registered on

Página 18 - 2.1.11 groupPowerCycle

24 2.2.5 findNewServerNetAddr Syntax: dscli findNewServerNetAddr NetAddr NetMask Description: Finds BMC on managed components that are not regist

Página 19 - 2.1.12 groupShutdownOs

25 2.2.7 deleteServer Syntax: dscli deleteServer Component [/force] Description: Deletes the specified managed component that is registered on th

Página 20

26 2.2.9 setServerProperty Syntax: dscli setComponentProperty Component PropertyName Value Description: Sets the property of a managed component.

Página 21

27 PropertyName Contents Value DefaultSERVER_SUBNETMASK_1 *1 Specify subnet mask of the BMC IP address. IP address format 255.255.255.0 SERVER_SU

Página 22 - 2.2.1 getServerList

28 2.2.11 getServerGroup Syntax: dscli getServerGroup Component Description: Display the name of group that a managed component belongs to. Optio

Página 23 - 2.2.3 getServerNameByGuid

2 2.2.26 setSensorLevel... 46 2.2.

Página 24 - 2.2.4 findNewServer

29 2.2.13 getServerProperty Syntax: dscli getServerProperty Component PropertyName Description: Displays the specified property of a managed compo

Página 25 - 2.2.6 createServer

30 BMC LAN2 IP Address Extra BMC IP address to connect to the managed component via LAN. BMC LAN2 Subnet Mask Subnet mask of the extra BMC IP addre

Página 26 - 2.2.8 checkConnection

31 2.2.15 getDeviceId Syntax: dscli getDeviceId Component Description: Obtains management controller information of the managed component. Option

Página 27 - 2.2.9 setServerProperty

32 2.2.17 getProductName Syntax: dscli getProductName Component Description: Obtains the product name and serial number of a managed component. O

Página 28 - 2.2.10 moveServer

33 2.2.19 setShutdownPolicy Syntax: dscli setShutdownPolicy Component KeyName Value Description: Changes shutdown policy of NEC ESMPRO Agent Exten

Página 29 - 2.2.12 setCurrentPort

34 KeyName Contents Value SCH_SHUTDOWN_WAIT Specify delay time in seconds to shutdown the managed component after shutdown OS command is issued. *

Página 30 - 2.2.14 getServerInfo

35 2.2.21 setPowerRestoreDelay Syntax: dscli setPowerRestoreDelay Component DelayTime [/x Policy] Description: Changes the power option that speci

Página 31

36 2.2.22 getPowerRestoreDelay Syntax: dscli getPowerRestoreDelay Component Description: Obtains power option that specifies working of a managed

Página 32 - 2.2.16 getGuid

37 /x ModuleNo Specify the CPU/IO module number (0 or 1) if the managed component is a fault tolerant server. This parameter is valid for the networ

Página 33 - 2.2.18 getSoftwareInfo

38 KeyName Contents Value CFG_LAN_MANAGE1_IP_LAN1 LAN1: Alert Receiver/ management PC(1) IP address IP address format CFG_LAN_MANAGE2_ALERT_LAN1 L

Página 34 - 2.2.19 setShutdownPolicy

3 2.6.7 clearPermitIpAddr ...82 2.7 Use

Página 35 - 2.2.20 getShutdownPolicy

39 KeyName Contents Value CFG_SERIAL_BAUDRATE WAN/Direct: Baud Rate 1: 9600bps 2: 19.2Kbps 3: 57.6Kbps 4: 115.2Kbps CFG_SERIAL_FLOW_CONTROL WAN/D

Página 36 - 2.2.21 setPowerRestoreDelay

40 KeyName Contents Value CFG_SERIAL_MANAGE2_IP WAN/Direct Alert Receiver (2) IP address IP address format CFG_SERIAL_MANAGE3_IP WAN/Direct Alert

Página 37 - 2.2.23 setBmcInfo

41 KeyName Contents Value CFG_NETWORK_DNS_SERVER Network Property: Basic DNS Server IP address format CFG_NETWORK_HOST_NAME Network Property: Basic

Página 38

42 KeyName Contents Value CFG_MAIL_ALERT_SERVER Alert Mail Alert: SMTP Server SMTP Server Up to 255 characters CFG_MAIL_ALERT_PORT Alert Mail Alert

Página 39

43 KeyName Contents Value CFG_SNMP_ALERT Alert SNMP Alert: Alert 0: Disabled 1: Enabled CFG_SNMP_COMPUTER_NAME Alert SNMP Alert: Computer Name Up t

Página 40

44 KeyName Contents Value CFG_MISCELLANEOUS_PEF Other: Platform Event Filter Platform Event Filter 0: Disabled 1: Enabled

Página 41

45 2.2.24 getBmcInfo Syntax: dscli getBmcInfo Component [/x ModuleNo] Description: Obtains BMC configuration information of a specified managed co

Página 42

46 2.2.25 setAuthKey Syntax: dscli setAuthKey Component OldPassword NewPassword SelectAuthKey Description: Changes the authentication key, PPP ser

Página 43

47 Type Specify an alert type. SNMP: SNMP alert MAIL: MAIL alert SensorName Specify the key name of sensor. See the following list. Level1 Specify

Página 44 - Receiver

48 SensorName Contents Level1 Level2 Level3COOL_DEV_ABNORMAL Cooling Device (Monitoring Abnormal State) OK OK OK TRANSITION_PW_SAVE Transition t

Página 45

4 Trademarks EXPRESSBUILDER and NEC ESMPRO are registered trademarks of NEC Corporation. Microsoft, Windows, Windows Vista, Windows Server are regi

Página 46 - 2.2.24 getBmcInfo

49 See the following list for a fault tolerant server. OK : Enable to change, NG : Disable to change SensorName Contents Level1 Level2 Level3TE

Página 47 - 2.2.26 setSensorLevel

50 SensorName Contents Level1 Level2 Level3PROCESSOR_DEGRADED Processor(Monitoring Degraded State) NG NG OK MODULE_BOARD_DEGRADED Module/Board(Mo

Página 48

51 2.2.27 getSensorLevel Syntax: dscli getSensorLevel Component Type Description: Obtains separate setting at the alert level of BMC configuration

Página 49

52 2.2.28 getAgentExtensionLog Syntax: dscli getAgentExtensionLog Component Description: Obtains the application logs of the NEC ESMPRO Agent Exte

Página 50

53 2.2.29 testAlert Syntax: dscli testAlert Component Target Description: Executes an alert test. You can confirm the result of test using 2.2.3

Página 51

54 2.2.30 getTestAlertStatus Syntax: dscli getTestAlertStatus Component Target Description: Obtains the state of an alert test. The parameter supp

Página 52 - 2.2.27 getSensorLevel

55 2.2.32 getPowerStatus Syntax: dscli getPowerStatus Component Description: Obtains the power state of a specified managed component. Options: Co

Página 53 - 2.2.28 getAgentExtensionLog

56 2.2.34 getPanelInfo Syntax: dscli getPanelInfo Component [/x ModuleNo] Description: Obtains the following state as the front panel information

Página 54 - 2.2.29 testAlert

57 2.2.35 powerOn Syntax: dscli powerOn Component [/p] Description: Turns on a specified managed component. If the POWER switch needs to be presse

Página 55 - 2.2.31 getServerStatus

58 2.2.37 reset Syntax: dscli reset Component [/p] Description: Forcibly resets a specified managed component. IMPORTANT:  Since remote power c

Página 56 - 2.2.33 getStatusLamp

5 About This Document This document introduces command line interface of the component management utility "NEC ESMPRO Manager". Before at

Página 57 - 2.2.34 getPanelInfo

59 2.2.38 powerCycle Syntax: dscli powerCycle Component [/p] Description: Forcibly turns off a specified managed component and then turns it on.

Página 58 - 2.2.36 powerOff

60 2.2.39 shutdownOs Syntax: dscli shutdownOs Component [/force] Description: Shut downs the operating system on a managed component. This com

Página 59 - 2.2.37 reset

61 2.2.41 clearSel Syntax: dscli clearSel Component [/force] Description: Clears the System Event Log (SEL) area on a managed component. Options:

Página 60 - 2.2.38 powerCycle

62 FileName Specify the filename with path name for saving the IPMI information. /x ModuleNo Specify the CPU/IO module number (0 or 1) if the manage

Página 61 - 2.2.40 dumpSwitch

63 /x ModuleNo Specify the CPU/IO module number (0 or 1) if the managed component is a fault tolerant server. If you omit this parameter for the faul

Página 62 - 2.2.43 getIpmiInfo

64 2.2.47 setBmcIpSync Syntax: dscli setBmcIpSync Component Value Description: Changes BMC IP Address Synchronization of NEC ESMPRO Agent Extensio

Página 63 - 2.2.45 getSensorStatus

65 2.2.49 getBladeSlotId Syntax: dscli getBladeSlotId Component Description: Execute 2.2.41 getIpmiInfo command previously. Obtains enclosure ID

Página 64 - 2.2.46 getConsoleLog

66 2.2.51 getBmcUserList Syntax: dscli getBmcUserList Component Description: Displays a list of user accounts that is set in the BMC configuration

Página 65 - 2.2.48 getBmcIpSync

67 2.2.52 setBmcUserInfo Syntax: dscli setBmcUserInfo Component UserId KeyName Values Description: Changes the user account information for the BM

Página 66 - 2.2.50 deleteBmcUser

68 2.2.54 setPowerRestorePolicy Syntax: dscli setPowerRestorePolicy Component Policy Description: Changes AC-Link policy that specifies working of

Página 67 - 2.2.51 getBmcUserList

6 Chapter1 About Command Line Interface The NEC ESMPRO Manager command line interface provides a set of commands that can control managed component

Página 68 - 2.2.53 getBmcUserInfo

69 2.2.56 getSystemFtLamp Syntax: dscli getSystemFtLamp Component Description: Obtains the state of System FT LED if the managed component is a fa

Página 69 - 2.2.55 getPowerRestorePolicy

70 2.3 EM Card Management Commands The following component management commands can be used for an EM card. However, the MAC address cannot be spec

Página 70 - 2.2.56 getSystemFtLamp

71 2.3.2 getEmActiveState Syntax: dscli getEmActiveState EmCard Description: Displays state of active/standby of the specified EM card. Options:

Página 71 - 2.3.1 getEmCardList

72 2.3.4 getEmStatusLamp Syntax: dscli getEmStatusLamp EmCard [/x SwmSlotNumber] Description: Obtains the state of a specified EM card or the swi

Página 72 - 2.3.3 identifyEm

73 2.4 Chassis Management Commands 2.4.1 getBladeEnclosureList Syntax: dscli getBladeEnclosureList Description: Displays the list of the blade

Página 73 - 2.3.4 getEmStatusLamp

74 The following shows an example. CPU Blade: 1: SERVER_0001 2: SERVER_0002 3,4: SERVER_0003 (Double-wide) 5: Not installed 6: Not registered 7:

Página 74 - 2.4.2 getChassisSlotState

75 2.4.4 setChassisProperty Syntax: dscli setChassisProperty ChassisName PropertyName Value Description: Sets the chassis property of a chassis.

Página 75 - 2.4.3 getChassisInfo

76 2.4.6 setBladeAutoSetting Syntax: dscli setBladeAutoSetting ChassisName SlotNumber PropertyName Value Description: This command is effective o

Página 76 - 2.4.5 getChassisProperty

77 2.4.7 getBladeAutoSetting Syntax: dscli getBladeAutoSetting ChassisName SlotNumber Description: This command is effective only to the chassis

Página 77 - 2.4.6 setBladeAutoSetting

78 2.5 Communication Management Commands 2.5.1 connect Syntax: dscli connect Component Description: Connects to a managed component with via mo

Página 78 - 2.4.7 getBladeAutoSetting

7 1.2 How to Execute Commands To execute a command, enter the command following the command prompt as shown below. dscli CommandName [Option, …] d

Página 79 - 2.5.3 getConnectionStatus

79 2.6 Environment Setting Commands 2.6.1 setOption Syntax: dscli setOption OptionName Value Description: Sets an option of the NEC ESMPRO Mana

Página 80 - 2.6.1 setOption

80 2.6.2 getOption Syntax: dscli getOption OptionName Description: Displays an option of the NEC ESMPRO Manager. Options: OptionName Specify a

Página 81 - 2.6.3 getPermitIpAddrList

81 2.6.4 isPermitIpAddr Syntax: dscli isPermitIpAddr CheckIpAddr Description: Checks whether a specified IP address is permitted for login from a

Página 82 - 2.6.6 removePermitIpAddr

82 2.6.7 clearPermitIpAddr Syntax: dscli clearPermitIpAddr Description: Removes all IP address ranges in which login from a Web client is permit

Página 83 - 2.6.7 clearPermitIpAddr

83 2.7 User Management Commands 2.7.1 createUser Syntax: dscli createUser UserName Password Description: Registers a new user that can login to

Página 84 - 2.7.3 getUserList

84 2.7.4 setUserProperty Syntax: dscli setUserProperty UserName PropertyName Value Description: Sets a property of a specified user. Options: Us

Página 85 - 2.7.4 setUserProperty

85 PropertyName Contents Value Default Admini-strator Ope-ratorUL_REMOTE_BATCH Specify the enable/disable of Remote Batch function. 0: Disabled 1

Página 86 - 2.7.5 getUserProperty

86 2.8 Other Commands 2.8.1 getApplicationLog Syntax: dscli getApplicationLog [Number] Description: Displays the latest application logs up to

Página 87 - 2.8 Other Commands

8 1.3 Execution Results All the commands return the end status. If an error has occurred, they return an error message. The end status of all the c