7.39. CURMINUTE Control procedure
7.39.1. CURMINUTE Control (Current time)
CMD Data1 Data2 Data3 Data4 Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x31)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x31) : CURMINUTE parameter
Value: 0 ~ 59 (range)
7.39.2. Current CURMINUTE state read
CMD Data1 Data2 Data3 Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x31)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x31) : CURMINUTE parameter
CMD Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current MINUTE getting value
0 ~ 59 (range)