NEC LCD8205 Manual do Utilizador Página 68

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 79
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 67
68
7.43. CURTEMP_MAIN Control procedure
7.43.1. Current main Temperature state read
CMD Data1 Data2 Data3 Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x37)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x37) : CURTEMP_MAIN parameter
CMD Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current Temperature getting value
7.44. CURTEMP_AUX Control procedure
7.44.1. Current aux Temperature state read
CMD Data1 Data2 Data3 Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x38)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x38) : CURTEMP_AUX parameter
CMD Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current Temperature getting value